Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Emerg Microbes Infect ; 12(1): 2157338, 2023 Dec.
Article in English | MEDLINE | ID: covidwho-2222491

ABSTRACT

Cytokine dynamics in patients with coronavirus disease 2019 (COVID-19) have been studied in blood but seldomly in respiratory specimens. We studied different cell markers and cytokines in fresh nasopharyngeal swab specimens for the diagnosis and for stratifying the severity of COVID-19. This was a retrospective case-control study comparing Myeloperoxidase (MPO), Adenosine deaminase (ADA), C-C motif chemokine ligand 22 (CCL22), Tumour necrosis factor alpha (TNFα) and Interleukin-6 (IL-6) mRNA expression in 490 (327 patients and 163 control) nasopharyngeal specimens from 317 (154 COVID-19 and 163 control) hospitalized patients. Of the 154 COVID-19 cases, 46 died. Both total and normalized MPO, ADA, CCL22, TNFα, and IL-6 mRNA expression levels were significantly higher in the nasopharyngeal specimens of infected patients when compared with controls, with ADA showing better performance (OR 5.703, 95% CI 3.424-9.500, p < 0.001). Receiver operating characteristics (ROC) curve showed that the cut-off value of normalized ADA mRNA level at 2.37 × 10-3 had a sensitivity of 81.8% and specificity of 83.4%. While patients with severe COVID-19 had more respiratory symptoms, and elevated lactate dehydrogenase, multivariate analysis showed that severe COVID-19 patients had lower CCL22 mRNA (OR 0.211, 95% CI 0.060-0.746, p = 0.016) in nasopharyngeal specimens, while lymphocyte count, C-reactive protein, and viral load in nasopharyngeal specimens did not correlate with disease severity. In summary, ADA appears to be a better biomarker to differentiate between infected and uninfected patients, while CCL22 has the potential in stratifying the severity of COVID-19.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , Interleukin-6/genetics , Tumor Necrosis Factor-alpha/genetics , Retrospective Studies , Adenosine Deaminase/genetics , Adenosine Deaminase/analysis , Adenosine Deaminase/metabolism , Case-Control Studies , Peroxidase , Ligands , SARS-CoV-2/genetics , SARS-CoV-2/metabolism , Cytokines , Chemokines , Nasopharynx , Chemokine CCL22
2.
Microbiol Spectr ; : e0196222, 2022 Nov 29.
Article in English | MEDLINE | ID: covidwho-2137460

ABSTRACT

Accurate and simple diagnostic tests for coronavirus disease 2019 (COVID-19) are essential components of the pandemic response. In this study, we evaluated a one-tube reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay coupled with clustered regularly interspaced short palindromic repeat (CRISPR)-associated protein-mediated endpoint detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in clinical samples. RT-LAMP-CRISPR is fast and affordable, does not require bulky thermocyclers, and minimizes carryover contamination risk. Results can be read either visually or with a fluorometer. RT-LAMP-CRISPR assays using primers targeting a highly expressed nsp8 gene and previously described nucleocapsid (N) gene primers were designed. The analytical characteristics and diagnostic performance of RT-LAMP-CRISPR assays were compared to those of a commercial real-time RT-PCR E gene assay. The limits of detection (LODs) of the nsp8 and N RT-LAMP-CRISPR assays were 750 and 2,000 copies/mL, which were higher than that of the commercial real-time RT-PCR assay (31.3 copies/mL). Despite the higher LOD, RT-LAMP-CRISPR assays showed diagnostic sensitivity and specificity of 98.6% and 100%, respectively, equivalent to those of the real-time RT-PCR assay (P = 0.5). The median fluorescence reading from the nsp8 assay (378.3 raw fluorescence unit [RFU] [range, 215.6 to 592.6]) was significantly higher than that of the N gene assay (342.0 RFU [range, 143.0 to 576.6]) (P < 0.0001). In conclusion, we demonstrate that RT-LAMP-CRISPR assays using primers rationally designed from highly expressed gene targets are highly sensitive, specific, and easy to perform. Such assays are a valuable asset in resource-limited settings. IMPORTANCE Accurate tests for the diagnosis of SARS-CoV-2, the virus causing coronavirus disease 2019 (COVID-19), are important for timely treatment and infection control decisions. Conventional tests such as real-time reverse transcription-PCR (RT-PCR) require specialized equipment and are expensive. On the other hand, rapid antigen tests suffer from a lack of sensitivity. In this study, we describe a novel assay format for the diagnosis of COVID-19 that is based on principles of loop-mediated isothermal amplification (LAMP) and clustered regularly interspaced short palindromic repeat (CRISPR)-Cas chemistry. A major advantage of this assay format is that it does not require expensive equipment to perform, and results can be read visually. This method proved to be fast, easy to perform, and inexpensive. The test compared well against an RT-PCR assay in terms of the ability to detect SARS-CoV-2 RNA in clinical samples. No false-positive test results were observed. The new assay format is ideal for SARS-CoV-2 diagnosis in resource-limited settings.

3.
Clin Infect Dis ; 75(1): e76-e81, 2022 08 24.
Article in English | MEDLINE | ID: covidwho-1852993

ABSTRACT

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can infect human and other mammals, including hamsters. Syrian (Mesocricetus auratus) and dwarf (Phodopus sp.) hamsters are susceptible to SARS-CoV-2 infection in the laboratory setting. However, pet shop-related Coronavirus Disease 2019 (COVID-19) outbreaks have not been reported. METHODS: We conducted an investigation of a pet shop-related COVID-19 outbreak due to Delta variant AY.127 involving at least 3 patients in Hong Kong. We tested samples collected from the patients, environment, and hamsters linked to this outbreak and performed whole genome sequencing analysis of the reverse transcription polymerase chain reaction (RT-PCR)-positive samples. RESULTS: The patients included a pet shop keeper (Patient 1), a female customer of the pet shop (Patient 2), and the husband of Patient 2 (Patient 3). Investigation showed that 17.2% (5/29) and 25.5% (13/51) environmental specimens collected from the pet shop and its related warehouse, respectively, tested positive for SARS-CoV-2 RNA by RT-PCR. Among euthanized hamsters randomly collected from the storehouse, 3% (3/100) tested positive for SARS-CoV-2 RNA by RT-PCR and seropositive for anti-SARS-CoV-2 antibody by enzyme immunoassay. Whole genome analysis showed that although all genomes from the outbreak belonged to the Delta variant AY.127, there were at least 3 nucleotide differences among the genomes from different patients and the hamster cages. Genomic analysis suggests that multiple strains have emerged within the hamster population, and these different strains have likely transmitted to human either via direct contact or via the environment. CONCLUSIONS: Our study demonstrated probable hamster-to-human transmission of SARS-CoV-2. As pet trading is common around the world, this can represent a route of international spread of this pandemic virus.


Subject(s)
COVID-19 , SARS-CoV-2 , Animals , Cricetinae , Disease Outbreaks , Female , Hong Kong/epidemiology , Humans , Mammals , RNA, Viral/genetics , SARS-CoV-2/genetics
4.
Expert Rev Mol Diagn ; 21(7): 741-747, 2021 07.
Article in English | MEDLINE | ID: covidwho-1236167

ABSTRACT

OBJECTIVES: Sensitive molecular diagnostic assays are essential for COVID-19 diagnosis. We evaluated the Hecin Scientific SARS-CoV-2 nucleic acid test kit, a dual-target real-time RT-PCR assay targeting the SARS-CoV-2 N and ORF1ab genes. METHODS: The Hecin test kit's diagnostic performance in detecting SARS-CoV-2 RNA was compared to the LightMix Modular SARS and Wuhan CoV E-gene kit (TIB Molbiol) and an in-house single-tube nested real-time RT-PCR using 296 clinical specimens, 11 proficiency testing samples, and 30 low-positive deep throat saliva and nasopharyngeal swab (NPS) samples pooled into negative samples in ratios of 1:5, 1:10, and 1:30. RESULTS: The limit-of-detection of the Hecin test kit was around 500 dC/mL for the N and ORF1ab targets. Sensitivity and specificity of the Hecin test kit were 98.1% (95% CI: 93.4-99.8%) and 100% (98.1-100%), respectively, when measured against the reference method. The Hecin test kit showed fair sensitivity (80%) in low-positive NPS samples pooled in ratios of 1:5 and 1:10. Its performance in pooled samples could be dramatically improved by adjusting the assay Ct cutoff. CONCLUSION: The Hecin test kit enables sensitive and specific detection of SARS-CoV-2 in clinical samples and pooled samples.


Subject(s)
COVID-19 Nucleic Acid Testing , COVID-19 , Real-Time Polymerase Chain Reaction , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/genetics , Specimen Handling , COVID-19/diagnosis , COVID-19/genetics , Humans , RNA, Viral/genetics
5.
Int J Mol Sci ; 21(16)2020 Aug 07.
Article in English | MEDLINE | ID: covidwho-714483

ABSTRACT

Sensitive molecular assays are critical for coronavirus disease 2019 (COVID-19) diagnosis. Here, we designed and evaluated two single-tube nested (STN) real-time RT-PCR assays, targeting SARS-CoV-2 RdRp/Hel and N genes. Both STN assays had a low limit of detection and did not cross react with other human coronaviruses and respiratory viruses. Using 213 initial respiratory specimens from suspected COVID-19 patients, the sensitivity of both the STN COVID-19-RdRp/Hel and the STN COVID-19-N assays was 100% (99/99), while that of the comparator non-nested N assay was 95% (94/99). Among 108 follow-up specimens from confirmed COVID-19 patients who tested negative by the non-nested COVID-19-RdRp/Hel assay, 28 (25.9%) were positive for SARS-CoV-2 by the STN COVID-19-RdRp/Hel or the STN COVID-19-N assay. To evaluate the performance of our novel STN assays in pooled specimens, we created four sample pools, with each pool consisting of one low positive specimen and 49 negative specimens. While the non-nested COVID-19-RdRp/Hel assay was positive in only one of four sample pools (25%), both of the STN assays were positive in two of four samples pools (50%). In conclusion, the STN assays are highly sensitive and specific for SARS-CoV-2 detection. Their boosted sensitivity offers advantages in non-traditional COVID-19 testing algorithms such as saliva screening and pooled sample screening during massive screening.


Subject(s)
Betacoronavirus/genetics , Coronavirus Infections/virology , Molecular Diagnostic Techniques/methods , Pneumonia, Viral/virology , Real-Time Polymerase Chain Reaction/methods , Betacoronavirus/pathogenicity , COVID-19 , Coronavirus Infections/diagnosis , Coronavirus Nucleocapsid Proteins , Coronavirus RNA-Dependent RNA Polymerase , Humans , Molecular Diagnostic Techniques/standards , Nucleocapsid Proteins/genetics , Pandemics , Phosphoproteins , Pneumonia, Viral/diagnosis , RNA-Dependent RNA Polymerase/genetics , Real-Time Polymerase Chain Reaction/standards , Respiratory Mucosa/virology , SARS-CoV-2 , Sensitivity and Specificity , Viral Nonstructural Proteins/genetics
6.
Lancet Infect Dis ; 20(9): 1051-1060, 2020 09.
Article in English | MEDLINE | ID: covidwho-597077

ABSTRACT

BACKGROUND: A cruise ship is a closed-off environment that simulates the basic functioning of a city in terms of living conditions and interpersonal interactions. Thus, the Diamond Princess cruise ship, which was quarantined because of an onboard outbreak of COVID-19 in February, 2020, provides an opportunity to define the shedding pattern of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and patient antibody responses before and after the onset of symptoms. METHODS: We recruited adult (≥18 years) passengers from Hong Kong who had been on board the Diamond Princess cruise ship docked in Yokohama, Japan in February, 2020. All participants had been found to be negative for SARS-CoV-2 by RT-PCR 4 days before disembarking and were transferred to further quarantine in a public estate in Hong Kong, where they were recruited. Participants were prospectively screened by quantitative RT-PCR (RT-qPCR) of nasopharyngeal and throat swabs, and serum IgG and IgM against internal nucleoprotein and the surface spike receptor-binding protein (RBD) of SARS-CoV-2 at baseline (upon entering quarantine) and on days 4, 8, and 12 of quarantine. FINDINGS: On Feb 22, 2020, 215 adults were recruited, of whom nine (4%; 95% CI 2-8) were positive for SARS-CoV-2 by RT-qPCR or serology and were hospitalised. Of these nine patients, nasopharyngeal swab RT-qPCR was positive in eight patients (89%; 57-99) at baseline. All nine patients were positive for anti-RBD IgG by day 8. Eight (89%; 57-99) were simultaneously positive for nasopharyngeal swab RT-PCR and anti-RBD IgG. One patient who was positive for anti-RBD IgG and had a negative viral load had multifocal peripheral ground-glass changes on high-resolution CT that were typical of COVID-19. Five patients (56%; 27-81) with ground-glass changes on high-resolution CT were found to have higher anti-nucleoprotein-IgG OD values on day 8 and 12 and anti-RBD IgG OD value on day 12 than patients without ground-glass changes. Six (67%; 35-88) patients remained asymptomatic throughout the 14-day quarantine period. INTERPRETATION: Patients with COVID-19 can develop asymptomatic lung infection with viral shedding and those with evidence of pneumonia on imaging tend to have an increased antibody response. Positive IgG or IgM confirmed infection of COVID-19 in both symptomatic and asymptomatic patients. A combination of RT-PCR and serology should be implemented for case finding and contact tracing to facilitate early diagnosis, prompt isolation, and treatment. FUNDING: Shaw Foundation Hong Kong; Sanming-Project of Medicine (Shenzhen); High Level-Hospital Program (Guangdong Health Commission).


Subject(s)
Betacoronavirus/physiology , Coronavirus Infections/virology , Disease Outbreaks , Pneumonia, Viral/virology , Seroconversion , Virus Shedding , Adult , Aged , Betacoronavirus/genetics , Betacoronavirus/immunology , COVID-19 , Contact Tracing , Coronavirus Infections/diagnostic imaging , Coronavirus Infections/epidemiology , Coronavirus Infections/prevention & control , Female , Hong Kong , Humans , Japan/epidemiology , Male , Middle Aged , Pandemics/prevention & control , Pneumonia, Viral/diagnostic imaging , Pneumonia, Viral/epidemiology , Pneumonia, Viral/prevention & control , Quarantine , SARS-CoV-2 , Ships , Thorax/diagnostic imaging , Viral Load , Young Adult
7.
J Clin Virol ; 129: 104476, 2020 08.
Article in English | MEDLINE | ID: covidwho-401826

ABSTRACT

BACKGROUND: Rapid and sensitive diagnostic assays for SARS-CoV-2 detection are required for prompt patient management and infection control. The analytical and clinical performances of LightMix® Modular SARS and Wuhan CoV E-gene kit, a widely used commercial assay for SARS-CoV-2 detection, have not been well studied. OBJECTIVE: To evaluate the performance characteristics of the LightMix® E-gene kit in comparison with well-validated in-house developed COVID-19 RT-PCR assays. STUDY DESIGN: Serial dilutions of SARS-CoV-2 culture isolate extracts were used for analytical sensitivity evaluation. A total of 289 clinical specimens from 186 patients with suspected COVID-19 and 8 proficiency testing (PT) samples were used to evaluate the diagnostic performance of the LightMix® E-gene kit against in-house developed COVID-19-RdRp/Hel and COVID-19-N RT-PCR assays. RESULTS: The LightMix® E-gene kit had a limit of detection of 1.8 × 10-1 TCID50/mL, which was one log10 lower than those of the two in-house RT-PCR assays. The LightMix® E-gene kit (149/289 [51.6%]) had similar sensitivity as the in-house assays (144/289 [49.8%] for RdRp/Hel and 146/289 [50.5%] for N). All three assays gave correct results for all the PT samples. Cycle threshold (Cp) values of the LightMix® E-gene kit and in-house assays showed excellent correlation. Reproducibility of the Cp values was satisfactory with intra- and inter-assay coefficient of variation values <5%. Importantly, the LightMix® E-gene kit, when used as a stand-alone assay, was equally sensitive as testing algorithms using multiple COVID-19 RT-PCR assays. CONCLUSIONS: The LightMix® E-gene kit is a rapid and sensitive assay for SARS-CoV-2 detection. It has fewer verification requirements compared to laboratory-developed tests.


Subject(s)
Betacoronavirus/isolation & purification , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Molecular Diagnostic Techniques/methods , Pneumonia, Viral/diagnosis , RNA, Viral/analysis , Adolescent , Adult , Aged , Aged, 80 and over , Betacoronavirus/genetics , COVID-19 , COVID-19 Testing , Female , Humans , Limit of Detection , Male , Middle Aged , Pandemics , RNA, Viral/genetics , Reference Standards , Reproducibility of Results , SARS-CoV-2 , Sensitivity and Specificity , Time Factors , Young Adult
8.
Lancet ; 395(10238): 1695-1704, 2020 05 30.
Article in English | MEDLINE | ID: covidwho-232479

ABSTRACT

BACKGROUND: Effective antiviral therapy is important for tackling the coronavirus disease 2019 (COVID-19) pandemic. We assessed the efficacy and safety of combined interferon beta-1b, lopinavir-ritonavir, and ribavirin for treating patients with COVID-19. METHODS: This was a multicentre, prospective, open-label, randomised, phase 2 trial in adults with COVID-19 who were admitted to six hospitals in Hong Kong. Patients were randomly assigned (2:1) to a 14-day combination of lopinavir 400 mg and ritonavir 100 mg every 12 h, ribavirin 400 mg every 12 h, and three doses of 8 million international units of interferon beta-1b on alternate days (combination group) or to 14 days of lopinavir 400 mg and ritonavir 100 mg every 12 h (control group). The primary endpoint was the time to providing a nasopharyngeal swab negative for severe acute respiratory syndrome coronavirus 2 RT-PCR, and was done in the intention-to-treat population. The study is registered with ClinicalTrials.gov, NCT04276688. FINDINGS: Between Feb 10 and March 20, 2020, 127 patients were recruited; 86 were randomly assigned to the combination group and 41 were assigned to the control group. The median number of days from symptom onset to start of study treatment was 5 days (IQR 3-7). The combination group had a significantly shorter median time from start of study treatment to negative nasopharyngeal swab (7 days [IQR 5-11]) than the control group (12 days [8-15]; hazard ratio 4·37 [95% CI 1·86-10·24], p=0·0010). Adverse events included self-limited nausea and diarrhoea with no difference between the two groups. One patient in the control group discontinued lopinavir-ritonavir because of biochemical hepatitis. No patients died during the study. INTERPRETATION: Early triple antiviral therapy was safe and superior to lopinavir-ritonavir alone in alleviating symptoms and shortening the duration of viral shedding and hospital stay in patients with mild to moderate COVID-19. Future clinical study of a double antiviral therapy with interferon beta-1b as a backbone is warranted. FUNDING: The Shaw-Foundation, Richard and Carol Yu, May Tam Mak Mei Yin, and Sanming Project of Medicine.


Subject(s)
Coronavirus Infections/drug therapy , Interferon beta-1b/therapeutic use , Lopinavir/therapeutic use , Pneumonia, Viral/drug therapy , Ribavirin/therapeutic use , Ritonavir/therapeutic use , Adult , Betacoronavirus , COVID-19 , Drug Combinations , Drug Therapy, Combination , Female , Hong Kong , Hospitalization , Humans , Male , Middle Aged , Pandemics , SARS-CoV-2 , COVID-19 Drug Treatment
9.
Int J Mol Sci ; 21(7)2020 Apr 08.
Article in English | MEDLINE | ID: covidwho-42099

ABSTRACT

The pandemic novel coronavirus infection, Coronavirus Disease 2019 (COVID-19), has affected at least 190 countries or territories, with 465,915 confirmed cases and 21,031 deaths. In a containment-based strategy, rapid, sensitive and specific testing is important in epidemiological control and clinical management. Using 96 SARS-CoV-2 and 104 non-SARS-CoV-2 coronavirus genomes and our in-house program, GolayMetaMiner, four specific regions longer than 50 nucleotides in the SARS-CoV-2 genome were identified. Primers were designed to target the longest and previously untargeted nsp2 region and optimized as a probe-free real-time reverse transcription-polymerase chain reaction (RT-PCR) assay. The new COVID-19-nsp2 assay had a limit of detection (LOD) of 1.8 TCID50/mL and did not amplify other human-pathogenic coronaviruses and respiratory viruses. Assay reproducibility in terms of cycle threshold (Cp) values was satisfactory, with the total imprecision (% CV) values well below 5%. Evaluation of the new assay using 59 clinical specimens from 14 confirmed cases showed 100% concordance with our previously developed COVID-19-RdRp/Hel reference assay. A rapid, sensitive, SARS-CoV-2-specific real-time RT-PCR assay, COVID-19-nsp2, was developed.


Subject(s)
Betacoronavirus/genetics , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Genome, Viral , Pneumonia, Viral/diagnosis , RNA, Viral/analysis , Real-Time Polymerase Chain Reaction , COVID-19 , COVID-19 Testing , COVID-19 Vaccines , Humans , Pandemics , Reproducibility of Results , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2 , Sensitivity and Specificity
10.
Gastroenterology ; 159(1): 81-95, 2020 07.
Article in English | MEDLINE | ID: covidwho-40729

ABSTRACT

BACKGROUND & AIMS: Infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causes coronavirus disease 2019 (COVID-19), which has been characterized by fever, respiratory, and gastrointestinal symptoms as well as shedding of virus RNA into feces. We performed a systematic review and meta-analysis of published gastrointestinal symptoms and detection of virus in stool and also summarized data from a cohort of patients with COVID-19 in Hong Kong. METHODS: We collected data from the cohort of patients with COVID-19 in Hong Kong (N = 59; diagnosis from February 2 through February 29, 2020),and searched PubMed, Embase, Cochrane, and 3 Chinese databases through March 11, 2020, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. We analyzed pooled data on the prevalence of overall and individual gastrointestinal symptoms (loss of appetite, nausea, vomiting, diarrhea, and abdominal pain or discomfort) using a random effects model. RESULTS: Among the 59 patients with COVID-19 in Hong Kong, 15 patients (25.4%) had gastrointestinal symptoms, and 9 patients (15.3%) had stool that tested positive for virus RNA. Stool viral RNA was detected in 38.5% and 8.7% among those with and without diarrhea, respectively (P = .02). The median fecal viral load was 5.1 log10 copies per milliliter in patients with diarrhea vs 3.9 log10 copies per milliliter in patients without diarrhea (P = .06). In a meta-analysis of 60 studies comprising 4243 patients, the pooled prevalence of all gastrointestinal symptoms was 17.6% (95% confidence interval [CI], 12.3-24.5); 11.8% of patients with nonsevere COVID-19 had gastrointestinal symptoms (95% CI, 4.1-29.1), and 17.1% of patients with severe COVID-19 had gastrointestinal symptoms (95% CI, 6.9-36.7). In the meta-analysis, the pooled prevalence of stool samples that were positive for virus RNA was 48.1% (95% CI, 38.3-57.9); of these samples, 70.3% of those collected after loss of virus from respiratory specimens tested positive for the virus (95% CI, 49.6-85.1). CONCLUSIONS: In an analysis of data from the Hong Kong cohort of patients with COVID-19 and a meta-analysis of findings from publications, we found that 17.6% of patients with COVID-19 had gastrointestinal symptoms. Virus RNA was detected in stool samples from 48.1% patients, even in stool collected after respiratory samples had negative test results. Health care workers should therefore exercise caution in collecting fecal samples or performing endoscopic procedures in patients with COVID-19, even during patient recovery.


Subject(s)
Betacoronavirus/isolation & purification , Coronavirus Infections/prevention & control , Diarrhea/virology , Feces/virology , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Viral Load , Betacoronavirus/genetics , Betacoronavirus/pathogenicity , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques , Coronavirus Infections/diagnosis , Coronavirus Infections/epidemiology , Coronavirus Infections/transmission , Diarrhea/diagnosis , Diarrhea/epidemiology , Endoscopy, Gastrointestinal/standards , Gastrointestinal Tract/diagnostic imaging , Gastrointestinal Tract/virology , Hong Kong/epidemiology , Humans , Infection Control/standards , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Pneumonia, Viral/diagnosis , Pneumonia, Viral/epidemiology , Pneumonia, Viral/transmission , Prevalence , RNA, Viral/isolation & purification , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL